Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
BMJ Case Rep ; 15(12)2022 Dec 13.
Article in English | MEDLINE | ID: covidwho-2161823

ABSTRACT

We present a female kidney transplant patient under conventional immunosuppression therapy. Her humoral immunity study (anti-spike-specific antibodies) was negative after the initial regimen and the third dose of vaccination against COVID-19. The specific ex vivo cellular immune study against spike of SARS-CoV-2 by interferon gamma release assay (IGRA) also remained at non-response levels at different time points despite an optimal non-specific cell immune response assessment. However, the cellular immunity test by delayed-type hypersensitivity (DTH) with spike of SARS-CoV-2 was always positive since the vaccination scheme began. Only after COVID-19 infection has there been a seroconversion of the patient's antibody tests along with IGRA positivity. The use of DTH test to measure the immune response could be a better and earlier parameter of the actual immune status that helps us to predict the immune response in real life. Hybrid immunity combining vaccine and natural infection could be a stronger stimulator of the specific global immune response.


Subject(s)
COVID-19 , Kidney Transplantation , Female , Humans , SARS-CoV-2 , Patients , Vaccination , Immunity, Humoral , Antibodies, Viral , Immunity, Cellular
2.
Diagnostics (Basel) ; 12(6)2022 Jun 09.
Article in English | MEDLINE | ID: covidwho-1884057

ABSTRACT

OBJECTIVE: As we progress with mass vaccination against SARS-CoV-2, there are key questions about the immunogenicity of COVID-19 vaccines that still are not answered. Conventional methods to measure cellular immune responses are complex and expensive in a pandemic situation. PATIENTS AND METHODS: Forty healthy healthcare workers accepted to participate during the vaccination schedule with a mRNA vaccine against SARS-CoV-2. Measurement of Delayed-Type Hypersensitivity (DTH) cutaneous response after intradermal test of protein S of SARS-CoV-2 at day 35 and day 200 was performed. At the same time, a specific anti-RBD IgG using a classic ELISA before vaccination, and on days 0, 35, and 200 was performed. RESULTS: All 40 individuals had a positive DTH skin response at day 35, whereas 39 participants had a positive skin test at day 200. Moreover, although all 40 individuals showed a positive humoral response of specific IgG against spike protein at day 35, with most of them having significantly lower levels at day 200. CONCLUSION: DTH could be proposed as an ideal and easy method to predict cellular immunity response to mRNA vaccines 200 days after starting an immunization schedule with mRNA vaccine for COVID-19.

3.
Allergol Immunopathol (Madr) ; 50(3): 101-105, 2022.
Article in English | MEDLINE | ID: covidwho-1836059

ABSTRACT

BACKGROUND: Patients with primary antibody deficiencies, such as Common Variable Immunodeficiency (CVID), have some problems to assess immune response after coronavirus disease (COVID) vaccination. Cutaneous delayed-type hypersensitivity (DTH) has the potential to be used as a useful, simple, and cheaper tool to assess T-cell (T lymphocyte) function. METHODS: Seventeen patients with CVID, a rare disease, received two doses of the mRNA-based Pfizer-BioNTech COVID-19 vaccine. Humoral Immune Response (HIR) was determined by measuring specific immunoglobulin G (IgG) antibodies, and Cellular Immune Response (CIR) was evaluated using an ex vivo interferon-gamma release assay (IGRA) and in vivo by DTH skin test. RESULTS: Two weeks after the second dose of the vaccine, 12 out of 17 CVID patients have high optical density (OD) ratios of specific anti-spike protein (S) IgG whereas five patients were negative or low. Ex vivo CIR was considered positive in 14 out of 17 S1-stimulated patients. Unspecific stimulation was positive in all 17 patients showing no T-cell defect. A positive DTH skin test was observed in 16 CVID patients. The only patient with negative DTH also had negative ex vivo CIR. CONCLUSIONS: The use of DTH to evaluate CIR was validated with an optimal correlation with the ex vivo CIR. The CIR after vaccination in patients with antibody deficiencies seems to have high precision and more sensitivity to antibodies-based methods in CVID. CLINICAL IMPLICATIONS: There is a remarkable correlation between cutaneous DTH and ex vivo IGRA after COVID vaccination. A COVID-specific skin DTH test could be implemented in large populations. CAPSULE SUMMARY: Cutaneous delayed-type hypersensitivity has the potential to be used as a useful, simple, and cheaper tool to assess T-cell functioning.


Subject(s)
COVID-19 , Common Variable Immunodeficiency , Antibodies, Viral , BNT162 Vaccine , COVID-19/prevention & control , COVID-19 Vaccines , Humans , Immunity, Cellular , Immunity, Humoral , Immunoglobulin G , SARS-CoV-2 , Spike Glycoprotein, Coronavirus , Vaccination
5.
Vaccines (Basel) ; 9(11)2021 Nov 12.
Article in English | MEDLINE | ID: covidwho-1512750

ABSTRACT

Previously, the delayed-type hypersensitivity (DTH) cutaneous test with the spike protein of SARS-CoV-2 has been shown to be a simple in vivo method to measure T-cell functionality after natural infection and in vaccinated individuals. METHODS: Twenty-five kidney-transplanted recipients were immunized with two doses of the mRNA-based Pfizer-BioNTech COVID19 vaccine three weeks apart. Cell-immune response (CIR) was evaluated ten weeks later using an in vivo DTH skin test and in vitro with an interferon gamma release assay (IGRA). Humoral Immune Response (HIR) was determined by the measurement of specific IgG anti-S1 SARS-CoV-2. RESULTS: Ten weeks after the second dose of the vaccine, 23 out of 25 transplanted patients had a positive DTH skin test, while in vitro CIR was considered positive in 20 patients. Unspecific stimulation was positive in all 25 patients, showing no T-cell defect. Seven out of twenty-five patients had a negative specific anti-spike IgG. CIR was positive in all immune-competent control patients. CONCLUSIONS: DTH is a useful, simple, and cheaper tool that can be used to assess cellular immune response, with an excellent correlation with the in vitro CIR. CIR assessment after vaccination in these immunocompromised patients is an excellent complement to HIR-based methods. This skin test could be used if classical in vitro methods cannot be applied.

6.
Vaccines (Basel) ; 9(6)2021 Jun 01.
Article in English | MEDLINE | ID: covidwho-1259630

ABSTRACT

BACKGROUND: Monitoring cellular immune responses elicited in vaccinated individuals is highly complicated. METHODS: 28 individuals participated during the vaccination process with 12 BNT162b2 mRNA (Pfizer) vaccine. Specific anti-RBD IgG using a classic ELISA was performed in days 10 and 20 (after one dose of the vaccine) and on day 35 (after two vaccine doses) in serum samples of all participants. In parallel, DTH (delayed-type hypersensitivity) Skin Test using S protein was performed before (11/28) and after two doses (28/28) of the vaccine. RESULTS: 6/28 individuals were considered positive for the specific anti-RBD IgG positive at day 10, whereas all 28 individuals were positive at day 20. Moreover, 28/28 individuals increased the OD ratios at day 36 (2 doses). DTH cutaneous test was performed on 11/28 participants at day 20 (1 dose) showing 8/11 a positive reaction at 12 h. DTH of all participants was performed on day 36 (2 doses), showing 28/28 positive reactions at 12 h. CONCLUSION: This report describes the first publication of the results obtained using an in vivo method, the classical DTH response to the Spike protein to assess T-cell immune responses in vaccinated individuals. This affordable and simple test would help to answer basic immunogenicity questions on large-scale population vaccine studies.

7.
Clin Immunol ; 226: 108730, 2021 05.
Article in English | MEDLINE | ID: covidwho-1188419

ABSTRACT

OBJECTIVE: To understand the anti-virus adaptive immune response occurring during SARS-Cov-2 infection is necessary to have methods to investigate cellular and humoral components. The goal of this study has been to investigate the utility of a specific spike-DTH test using a coronavirus recombinant protein in COVID-19 patients. METHODS: DTH studies were performed by intradermal injection of a commercial recombinant spike protein from SARS-CoV-2 along with conventional serology studies. RESULTS: Fifty-one COVID-19 patients were studied showing 84,3% of concordance with spike-DTH and anti-RBD-IgG. Spike-DTH was superior to identify seven more COVID-19 individuals. A high specificity was found with no positive spike DTH reactions in the non-sick individuals. The skin test also showed more stable results over time while specific anti-RBD-IgG decreased gradually. Clinical severity groups also showed a progressive gradient of larger positive spike-DTH. CONCLUSION: Specific spike DTH test seems to be an easy method to study cell immune response.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/immunology , Hypersensitivity, Delayed/immunology , Spike Glycoprotein, Coronavirus/immunology , Antibodies, Viral/blood , Female , Humans , Immunity, Cellular , Immunoglobulin G/blood , Injections, Intradermal , Male , Middle Aged , Protein Domains , Recombinant Proteins , SARS-CoV-2/genetics
SELECTION OF CITATIONS
SEARCH DETAIL